• Legrand Single Phase Double Conversion UPS WHAD CAB 1250VA 310118

Legrand Single Phase Double Conversion UPS WHAD CAB 1250VA 310118

€744.62
Tax included

Legrand single-phase double conversion UPS for MV/LV transformer substations WHAD CAB 1250VA, 160 min at 50W autonomy with the following characteristics:

 

  • Voltage: QMT
  • Active power: 875 watts
  • Rated power: 1250 VA
  • Degree of protection: IP21
  • Height: 460 mm
  • Width: 160 mm
  • Depth: 425 mm
  • Series: Whad CAB, QMT
  • Autonomy: 160 minutes at 50 watts

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

The Legrand Whad CAB model UPS is an uninterruptible power supply for protection in MV/LV transformer substations complying with CEI 0-16 standard, with high-frequency PWM technology, On Line Double Conversion type, through-neutral, Rated Power 1250VA - 875 W, equipped with valve-regulated hermetic type storage batteries, contained inside the UPS in a special compartment or in one or more external cabinets, sized to ensure minimum autonomy.


 

The Whad CAB UPS is equipped with a CHARGE RESERVE that allows the batteries to maintain a reserve of power to ensure that the coil can always be reset and full cabin functionality restored.

 

The UPS rectifier consists of a control and regulation circuit (PFC), which in addition to normal rectifier functions provides:

  • Automatically correct the load power factor to return it to a value >0.99 already with an applied output load of 20% of the rated load
  • Power the inverter without requiring power from the batteries even at very low line voltage (grid-supplied operation for VIN values of 110 Vac at 50% of rated load)
  • Ensure total harmonic distortion of the input current THDIin < 3% without the addition of additional filters or components

     

The bypass circuit is designed and implemented in accordance with the following: Electromechanical switch, Microprocessor-controlled command and control logic that provides:

  • Automatically transfer the load directly to the primary grid without interrupting the power supply, upon the occurrence of the conditions of overload, overtemperature, out-of-tolerance DC voltage, and inverter failure
  • Automatically re-transfer the load from primary grid to inverter line, without power interruption, upon restoration of normal load conditions
  • If the primary grid and inverter are not synchronized, the bypass will have to be disabled

     

In order to safeguard batteries from damage from deep discharge, the minimum allowable battery voltage threshold automatically varies according to the applied load (default setting), while allowing the user the option of selecting fixed voltage threshold management.

 

Diagnostic and shutdown software, when properly installed in a PC connected to the UPS, provides access to all operating data, makes adjustments and settings of special functions, and controls shutdown of Windows and Linux operating systems.

 

Optional software enables hierarchical multiserver shotdown and remote UPS management for any operating system in a heterogeneous network (Windows, Novell, Linux, and popular Unix). Whad CAB is microprocessor-controlled and can display via an LED control panel alarms and operating modes as described below:

 

  • Normal operation
  • Output frequency not synchronized with input
  • Battery operation
  • Bypass operation
  • Faulty power module
  • Overload
  • Generic fault
  • Incorrect neutral connection
  • Power reserve
  • End of autonomy

     

General Characteristics:

  • On-line double conversion type of operation
  • Stand-alone expandable conventional UPS architecture
  • Pass-through Neutral Regime
  • Waveform in grid/battery operation Sinusoidal/Sinusoidal
  • Switching time Null

     

Input characteristics:

  • Nominal input voltage 230 V
  • Input voltage range 184V÷265V at 100% load
  • Minimum mains operating voltage 110V at 50% load
  • Input frequency 50 Hz or 60Hz (user selectable)
  • Total harmonic distortion of input current (THDIin) 3%
  • Power factor > 0.99
  • Inrush current Maximum 100% of load current

     

Output characteristics (mains operation):

  • Rated output voltage 230 V ± 1%
  • Rated/active output power 1250 VA / 875 W
  • Total harmonic distortion of output voltage on nominal linear load 1 %.
  • Total harmonic distortion of output voltage on nonlinear nominal load, P.F.=0.7 < 4 %
  • Rated output frequency 50 Hz or 60 Hz
  • Tolerance on output frequency Synchronized to input frequency; ± 1% when not synchronized
  • Crest factor on output current 3.5:1

     

Output characteristics (battery operation):

  • Rated output voltage 230 V ± 1%
  • Output frequency 50 Hz or 60 Hz ± 1%
  • Rated/active output power 1250 VA / 875 W
  • Total harmonic distortion of output voltage on nominal nonlinear load, P.F.=0.7 < 1 %

     

Battery characteristics:

  • Battery type Lead-acid, sealed, maintenance-free
  • Autonomy1 160 minutes at 50W
  • Unit capacity 9 Ah (12V)
  • Voltage of UPS battery / of battery modules 36V max. (series of 3*12V)
  • Battery module protection 2 fuses for each battery module

  • Brand
  • Reference
    LEG 310118
  • In stock
    10 Items
  • EAN13
    3414970646736

  • Type
    Uninterruptible Power Supply UPS
  • Rated Power
    1250VA
  • Active Power
    875W
  • Endurance
    160 minutes