ComPacT NSX is designed to optimize space and interrupter capacity for all standard and specific applications. This basic frame is supplied without a breaker, and is compatible with any type of breaker to be ordered separately. Icu interrupting capacity is 36kA at 415VAC 50/60Hz. Operating voltage is 690VAC 50/60Hz (limited to 440VAC 50/60Hz if differential protection is present). It can be equipped with a variety of optional functions and accessories. Dimensions are 185mm x 255mm x 110mm. Ensures compliance with international standards (IEC 60947), CCC, EAC and maritime specifications. ComPacT NSX400F is part of the Schneider Electric EcoStruxure Power architecture.
Advantages:
- Schneider Electric unmistakable green style for the entire ComPacT range
- Estimated 40% reduction in wiring time for panel builders. Experience easier installation thanks to new ergonomic front plate design
- Get confidence that all auxiliaries are in the right place and check that you have the right coil rating
- New ergonomic lever for easy manual switch operation
Technical features:
- Insulation suitability: Yes compliant with EN/IEC 60947-2
- Utilization category: A
- Mechanical durability: 15000 cycles complying with IEC 60947-2
- Mounting bracket: Back plate
- Elevation connection: Front
- Negative connection: Front
- Connection pitch: 45 mm
- Dimensions: height 255mm - width 185mm - depth 110mm
- Control type: On/off
- Mounting mode: Fixed
- Ambient air temperature for operation: -25/+70 degrees
- Ambient air temperature for storage: -50/+85 degrees
Rated maximum short-circuit breaking capacity:
- 85 kA at 240 V AC 50/60 Hz in accordance with UL 508
- 25 kA Icu at 500 V AC 50/60 Hz complying with IEC 60947-2
- 36 kA Icu at 380/415 V AC 50/60 Hz complying with IEC 60947-2
- 10 kA Icu at 660/690 V AC 50/60 Hz complying with IEC 60947-2
- 40 kA Icu at 220/240 V AC 50/60 Hz complying with IEC 60947-2
- 35 kA at 480V AC 50/60 Hz complying with UL 508
- 20 kA at 600V AC 50/60 Hz complying with UL 508
- 20 kA Icu at 525 V AC 50/60 Hz complying with IEC 60947-2
- 30 kA Icu at 440 V AC 50/60 Hz complying with IEC 60947-2
Rated short-circuit service breaking capacity:
- 36 kA at 380/415 V AC 50/60 Hz complying with IEC 60947-2
- 10 kA at 660/690 V AC 50/60 Hz complying with IEC 60947-2
- 40 kA at 220/240 V AC 50/60 Hz complying with IEC 60947-2
- 10 kA at 525 V AC 50/60 Hz complying with IEC 60947-2
- 25 kA at 500 V AC 50/60 Hz complying with IEC 60947-2
- 30 kA at 440 V AC 50/60 Hz complying with IEC 60947 -2
Electrical durability:
- 12000 cycles 440 V AC 50/60 Hz In/2 complying with IEC 60947-2
- 3000 cycles 690 V AC 50/60 Hz Compliant with IEC 60947-2
- 6000 cycles 440 V AC 50/60 Hz Complies with IEC 60947-2
- 6000 cycles 690 V AC 50/60 Hz In/2 Compliant with IEC 60947-2
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent