• Hager Differential Block 63A 4-Pole 300mA Type A 3-Module BF463N

Hager Differential Block 63A 4-Pole 300mA Type A 3-Module BF463N

€157.84
Tax included

Hager Differential Block:

  • Current Rating in 63A
  • 4 Poles
  • Rated differential current 300mA
  • Type A
  • 3 Modules

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

The differential blocks are mechanically designed to prevent mismating between the block and the circuit breaker: the rating of the block must always be equal to or greater than that of the circuit breaker. The plastic clamp on the side allows faster mounting of the block on the circuit breaker, and a push-button prevents possible tripping.

It is used to protect human health in the event of a ground fault (electrical leakage) or phase-to-ground electrocution, thus also providing protection against macro electrical shock, both direct and indirect, on exposed persons.

The type A differential block, ensures operation for AC and one-way pulsating type currents.

Features:

  • Rated operating voltage AC 230 / 400 V
  • Rated frequency 50 Hz
  • Right neutral position
  • Rated insulation voltage 500 V
  • Rated fault holding current 4000 V
  • Rated current at 40 °C 63 A
  • Frequency (ETIM numerical value range) 50 Hz
  • Total power dissipation 35.5 W
  • Power dissipated per pole 10.7 W
  • Electrical life and number of cycles 2000
  • Number of maneuvers (mechanical life) 2000
  • Dimensions: Depth of installed product 9.2 cm - Height of installed product 7 cm - Width of installed product 3.5 cm
  • Tightening torque 2.9Nm
  • High latching type for modular products Plastic
  • Low latching type for modular products NA
  • Top removability for modular fixtures yes
  • Minimum cross-section with flexible cable 16mm²
  • Minimum cross-section with rigid cable 25mm²
  • Enclosure degree of protection IP20
  • Type of protection differential A
  • Operating temperature -5/+40°C
  • Altitude 2000m
  • Tropicalized execution I

  • Brand
  • Reference
    HAG BF463N
  • In stock
    17 Items
  • EAN13
    3250611364542

  • Modules
    3
  • Poles
    4P
  • RCD Type
    A
  • Differential current
    0.3A
  • Amps
    63A
  • Circuit Protections
    Earth Leakage add-on Blocks