Hager thermal-magnetic circuit breaker, with the following characteristics:


  • Rated breaking capacity Icn AC according to IEC 60898-1 10 kA
  • Rated operating voltage AC 400V
  • AC supply voltage type
  • Rated insulation voltage 500V
  • Rated fault withstand current 6000V
  • Minimum threshold voltage (Ue min) 12V
  • Neutral position without neutral
  • Number of protected poles 4
  • Poles 4
  • Rated current : 50 amperes
  • DIN rail mounting mode
  • Tripping curve : C
  • Frequency: 50 to 60 Hz

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Curve C, trip threshold 5 to 10 times In, for application of ohmic-inductive circuits with medium inrush currents. It is widely used in domestic installations.


A circuit breaker is a safety device that can automatically (i.e., without external intervention) interrupt the flow of electric current in an electrical circuit in the event of an overcurrent.


Other technical characteristics:

  • Maximum power dissipated per pole according to product standard 9W
  • Total power dissipation 20.3W
  • Power dissipated per pole 5.4W
  • Degree of protection IP20
  • Electrical life and number of cycles 4000
  • Number of maneuvers (mechanical life) 20000
  • Suitable for DIN rail mounting: yes
  • High connection alignment for modular products aligned terminals
  • Low connection alignment for modular products aligned terminals
  • High connection type for modular products screw terminal
  • Tightening torque 2.8Nm
  • Low connection type for modular products Plastic
  • Low connection type for modular products quickconnect clamp
  • Top removal for modular fixtures: yes
  • Bottom removal for modular products yes
  • Suitable for flush mounting siCapacity downstream flex clamp. Condu. 1 / 25 mm²
  • Downstream terminal capacity rigid cond. 1 / 35 mm²
  • Input connection cross section 1 / 35 mm²
  • Screw cap mor. cable - line mm2 (flex.) 1 / 25 mm²
  • Delivery state downstream of cage terminal open
  • Delivery state upstream of cage terminal open
  • Accessory yes
  • With transparent label holder yes
  • Operating temperature -25...70 °C
  • Pollution degree/IEC60664/IEC60947-2 2
  • Energy limitation class I²t 3
  • Altitude 2000m
  • Storage/transport temperature -25/+80 °C
  • Calibration temperature 50 °C
  • Depth of installed product 70 mm
  • Height of installed product 83 mm
  • Width of installed product 70 mm
  • With pole of Neutral sectioned: no

  • Brand
  • Reference
    HAG NCN450A
  • In stock
    6 Items
  • EAN13
    3250614616020

  • Voltage
    400VAC
  • Modules
    4
  • Poles
    4P
  • Curve
    C
  • Breaking capacity
    10KA
  • Degree of protection
    IP20
  • Amps
    50A
  • Circuit Protections
    Circuit breakers