Bticino Smart DIN-mount Connected Load Management Module to monitor the consumption of the entire electrical system, feed/discharge loads, and set up scenarios with priority and non-priority loads.
When the maximum power stipulated by the user's contract is reached, non-priority loads will be temporarily de-energized to avoid possible and annoying blackouts. A toroid for input current measurement is provided.
Smart monitoring: Measures total power consumption via the included toroid.
Smart load management: Temporary disconnection of non-priority loads to avoid blackouts.
Integration with Home+Control App: View consumption and configure thresholds and priorities.
Universal power supply: 100-240 Va.c., compatible with any installation.
Compact format: 1 DIN module for simple and neat installations.
For operation, the FC80GCS load management module requires prior installation of 1 "smart energy kit" or No. 1 Gateway module + at least No. 1 power outlet or 1 connected contactor in order to use the smart load management function.
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
Allows you to measure your home's total power consumption via the included current toroid and display it in the Home + Control app for smartphones. The load management module can then detect when the contracted power (or the maximum consumption threshold defined in the App) is about to be exceeded and intelligently control connected loads (contactors and connected electrical outlets) according to predefined, easily customizable priorities.
The user can then set primary and secondary loads via the Home+Control app to avoid annoying blackouts and achieve a high level of comfort, while keeping their available contracted power unchanged.
This connected version offers the functions of:
Single-phase current measurement via current toroid (supplied with the load management module) and radio frequency data transmission to the connected network.
Suitable for homes, offices, and small businesses, the connected load management module is perfect for optimizing consumption, avoiding overloads, and improving energy efficiency.
| Feature | Detail |
|---|---|
| Voltage | 110 to 230 Vac |
| Operating frequency | 50/60 Hz |
| Maximum primary measured current | 80A AC |
| Transformation ratio | 1000 :1 |
| Rated short-time thermal current (Ith) | 3kA rms /1s |
| Rated dynamic current (Idyn) | 9kA |
| Rated insulation level | 3KV rms 50Hz/1min |
| Insulation class | Class A according to IEC61869-1 and IEC61869-2 |
| Rated Accuracy Class | Class 1 according to IEC61869-1 (+/-1% at Ipn 63A) |
| Rated Impulse Voltage (Uimp) | 4 kV |
| Overvoltage Category | II |
| Pollution degree | 2 |
| Rated operating voltage (Ue) | 100 - 240 V ~ |
| Feature | Detail |
|---|---|
| Type | Wireless mesh |
| Power level | < 100 mW |
| Band frequency | 2.4 to 2.4835 GHz |
| Type of Cable | Capacity |
|---|---|
| Copper cables without ferrule |
|
| Flexible copper cables with ferrule | 1x (1 - 1.5 mm²) |
| Feature | Detail |
|---|---|
| Protection | A gG breaker or fuse is recommended to protect the device against overloads and short circuits |
| Standard | Detail |
|---|---|
| EN 61869-1 | Applicable standard |
| EN 61869-2 | Applicable standard |
| EN 61010-1 | Applicable standard |