Fire-resistant FTG18M16 flexible power cable with G18 rubber insulation and LS0H M16 sheathing, halogen-free and low smoke emission. Ideal for safety installations in critical environments, with the following characteristics:
Section: 1x50 sq mm
Conductor diameter: 8.9 mm
Insulation thickness: 1.4 mm
Sheath thickness: 1.6 mm
Outer diameter: 17.6 mm
Electrical resistance: 0.386 ohm/km
Current carrying capacity in tube in air: 175 A
Current carrying capacity in free air: 207 A
The selling price is intended per meter.
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
Flexible power cable FTG18M16 is designed for maximum reliability under fire conditions, ensuring continuous operation for 120 minutes at 820 degrees, with direct exposure to fire and mechanical shock. Due to its construction with G18 rubber insulation and LS0H M16 sheathing, the cable is halogen-free and limits the spread of flames and development of toxic fumes, contributing to the safety of critical environments.
This cable consists of:
Red annealed copper conductor with flexible cord (class 5), providing excellent electrical conductivity
Helically wound glass/mica tape, for high temperature resistance
G18 rubber insulation, offering thermal and mechanical protection
LS0H (Low Smoke Zero Halogen) M16 sheathing, with excellent safety properties in case of fire
Designed to withstand harsh operating conditions, with a voltage rating of 0.6/1 kV and current carrying capacity up to 207 A in free air. It also withstands temperatures up to 250 degrees when short-circuited and has a maximum tensile stress of 50 N/mm², ensuring mechanical strength even in complex installations.
This cable can be installed indoors and outdoors, even in wet conditions, on masonry, metal structures, catwalks, pipes and conduits. It is also suitable for underground laying, even without additional protection, ensuring versatility and safety in any context.
Due to its high fire resistance and low smoke emissions, FTG18M16 cable is ideal for:
Security and emergency systems (emergency lighting, alarms)
Installations in railway stations, subways, airports and tunnels
Fire detection and extinguishing, automatic door opening, ventilation and air conditioning systems
Emergency telephone systems and critical infrastructure
| Feature | Value |
|---|---|
| Conductor | Flexible annealed red copper (Class 5) |
| Insulator | Rubber G18 |
| Tape | Glass/mica helically wound |
| Filler | Non-hygroscopic material |
| Outer sheath | LS0H M16 (blue) |
| Rated voltage | 0.6/1 kV |
| Fire resistance | PH120-F120 (120 min at 820°C) |
| Operating temperature | -15°C / +90°C |
| Installation temperature | Minimum -5°C |
| Maximum short-circuit temperature | 250°C |
| Maximum tensile stress | 50 N/mm² |
| Minimum bending radius | 14 times the outer diameter |
| Conductor diameter | 8.9 mm |
| Insulation thickness | 1.4 mm |
| Sheath thickness | 1.6 mm |
| Outer diameter | 17.6 mm |
| Electrical resistance | 0.386 ohm/km |
| Current flow rate in air tube | 175 A |
| Current flow rate in free air | 207 A |