• Abb Residual current device F204 63A 4P 300mA Type A F427839

Abb Residual current device F204 63A 4P 300mA Type A F427839

€200.62
Tax included

Abb Residual current device F204:

 

  • 63A rated current
  • 4 Poles
  • Rated residual current 300mA (0.3)
  • Type A
  • 4 Modules
  • Rated voltage 230/400V
  • Rated impulse withstand voltage 4 kV
  • AC Input Voltage Type

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Pure residual current devices without thermal-magnetic circuit breakers are circuit breakers that provide protection of persons against indirect contacts and additional protection against direct contacts according to IEC EN 61008-1 and IEC EN 61008-2-1.

 

As they lack a built-in circuit breaker, pure earth leakage circuit breakers must be protected against short circuits by appropriate circuit breakers or fuses.

 

The APR perturbation-resistant versions are devices specially designed to be immune to untimely trips caused by impulsive leakage due to maneuvering or atmospheric phenomena such as lightning strikes.

 

The Residual current device serves to protect people and not systems. The moment a person goes to touch it, it creates a circuit with the earth. The current instead of staying in the household circuit, uses the human body to go to ground.

 

 

The residual current device is a device in your electrical system. It is capable of opening the circuit, i.e., shutting off the power supply, the moment the current accidentally dissipates.

A residual current device offers protection in the case of current leakage but not in the case of surges. Instead, the circuit breaker is required for this type of problem.

 

A type A Residual current device tripping is provided for alternating sine differential currents and unidirectional pulsating differential currents applied suddenly or slowly increasing (IEC EN 61008-1).

 

Characteristics:

  • Reference standards: IEC/EN 61008 UL 1053
  • Residual current type: Type A
  • Rated voltage (Ur): 230/400 V
  • Rated operating voltage: 230 / 400 V AC
  • Rated insulation voltage (Ui): 500 V
  • Rated conditional short-circuit current (Inc): 10 kA
  • Rated service short-circuit rating (Ics): 1 kA
  • Leakage Current Type: A
  • Rated Frequency (f): 50 60 Hz
  • Power Loss: at Rated Operating Conditions per pole 4.4 W
  • Electrical Resistance: 10000 cycle(s)
  • Number of Poles: 4
  • Number of Modular Spacings per DIN Rail: 4
  • Operating Characteristic: Instantaneous
  • Position of Neutral Terminals: Right
  • Mounting Type: DIN-Rail
  • Connection capacity: Busbar 10 mm² - Rigid 25 ... 25 mm² - Flexible 25 ... 25 mm²
  • Nominal cross-section: 4 - Multi-Wired 0...25 mm² - 1 - Solid-Core 25...25 mm².

  • Brand
  • Reference
    ABB F427839
  • In stock
    1 Item
  • EAN13
    8012542783916

  • Voltage
    230/400VAC
  • Modules
    4
  • Poles
    4P
  • RCD Type
    A
  • Differential current
    0.3A
  • Amps
    63A
  • Circuit Protections
    Residual current devices

Comments (0)

No customer reviews for the moment.

16 other products in the same category

Viewed products

Loading...