• Multi-core shielded cable FG16OH2R16 2x2.5 sq. mm 0.6/1 kV

Multi-core shielded cable FG16OH2R16 2x2.5 sq. mm 0.6/1 kV Gray

€1.84
Tax included

FG16OH2R16 multi-core shielded cable, safety, shielding and flexibility for new generation electrical systems, with the following characteristics:

  • Section: 2x2.5 sq. mm

  • Rated voltage: 0.6/1 kV

  • Conductor diameter: 1.9 mm

  • Insulation thickness: 0.7 mm

  • Sheath thickness: 1.8 mm

  • Sheath outer diameter: 11 mm

  • Electrical resistance: 7.98 Ω/km

  • Current carrying capacity in air/tube: 30 A

Sale by the meter.

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

FG16OH2R16 shielded cable protection and reliability for power transmission

FG16OH2R16 2x2.5 sq mm 0.6/1 kV FG16OH2R16 cable is designed for applications where safety, shielding and durability are essential. With red copper braid shielding, the cable provides effective protection against electromagnetic interference, making it ideal for electrical installations in residential, tertiary and industrial environments.

Quality materials for high performance

The cable structure is based on flexible class 5 annealed red copper conductors, which ensure excellent electrical conductivity and good flexibility. G16 ethylpropylene rubber insulation, combined with a non-hygroscopic filler and an R16 PVC outer sheath, provides mechanical strength, thermal insulation and durability, even under harsh environmental conditions.

Versatile and CPR-compliant installation

With a voltage rating of 0.6/1 kV and a CPR rating of Cca-s3,d1,a3, the cable meets the reaction-to-fire requirements of the Construction Products Regulation, providing enhanced safety in the event of fire. It is suitable for fixed installation both indoors and outdoors, including in wet environments, on masonry, conduits, metal structures or underground, according to IEC 20-67.

Recommended applications.

The cable is ideal for:

  • Industrial and civil electrical installations

  • Wiring in environments where there is a risk of interference

  • Connections to electrical panels and power equipment

  • Installations in conduits, pipes, walls or in underground laying

  • Residential installations with shielding requirements

Technical Characteristics FG16OH2R16 Cable

ParameterValue
Section 2x2.5 sq. mm
Rated voltage 0.6/1 kV
Conductor Annealed red copper, class 5
Conductor diameter 1.9 mm
Insulation Ethylpropylene rubber G16
Insulation thickness 0.7 mm
Filler Non-hygroscopic material
Screen Red copper braid
Outer sheath PVC R16, color gray
Sheath thickness 1.8 mm
Sheath outer diameter 11 mm
Electrical resistance 7.98 Ω/km
Current carrying capacity 30 A (in air/pipe)
Maximum operating temperature 90°C
Max. short-circuit temperature 250°C
Min. laying temperature 0°C
Minimum operating temperature -15°C (without mechanical stress)
Tensile stress 50 N/mm²
Minimum bending radius 8 times the outer diameter
CPR Cca-s3,d1,a3
Sale By the meter

  • Brand
  • Reference
    9X9 FG16OH2R162X2,5
  • In stock
    956 Items

  • Colour
    Grey
  • Type
    FG16OH2R16
  • Cross-Section
    2.5 mmq
  • With yellow/green
    No
  • Number of cables
    2

Comments (0)

No customer reviews for the moment.

16 other products in the same category

Viewed products

Loading...