• Schneider TeSys LC1D Contactor 3P 9A AC3 110 V AC LC1D09F7

Schneider TeSys LC1D Contactor 3P 9A AC3 110 V AC LC1D09F7

€29.71
Tax included

Schneider TeSys LC1D contactor with the following characteristics:

  • Number of poles: 3
  • Rated operating voltage
  • Ue: <= 690 V "AC" 25...400 Hz Power circuit - <= 300 V DC Power circuit
  • Rated use current
  • Ie: 9 A 60 °C) "AC" AC-3 for Power circuit at <= 440 V - 25 A 60 °C) "AC" AC-1 for Power circuit at <= 440 V - 9 A 60 °C) "AC" AC-3e for Power circuit at <= 440 V
  • Contact pole composition: 3 NO
  • Contact compatibility: M4
  • Auxiliary contact composition: 1 NO + 1 NC
  • Rated impulse withstand voltage: 6 kV in accordance with IEC 60947

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

LC1D09BD is a compact 3-pole TeSys D contactor from Schneider Electric for motor applications. Rated 9 A AC-3 4 kW at 400 V, it includes a 24 V DC coil and 1NA+1NC auxiliary contacts. Can be used in safety applications due to the certified NC mirror contact. Compact, DIN-rail-mounted, it ensures high reliability and durability. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium (RoHS/REACH) compliant.


Advantages:

  • Compact product, 45 mm wide, for DIN rail and panel mounting.
  • Separation between power and control circuits, easy front access to coil and auxiliary contact connections.
  • Equipped with a 24 V DC coil for easy integration into all control systems.
  • Features 2 built-in 1NA+1NC auxiliary contacts.
  • High electrical endurance, guaranteed for 2 million cycles at 9 A AC-3 440 V

Rated operating voltage:

  • <= 690 V "AC" 25...400 Hz Power circuit
  • <= 300 V DC Power circuit

Rated use current:

  • 9 A 60 °C) "AC" AC-3 for Power circuit at <= 440 V
  • 25 A 60 °C) "AC" AC-1 for Power circuit at <= 440 V
  • 9 A 60 °C) "AC" AC-3e for Power circuit at <= 440 V

Motor power:

  • 2.2 kW at 220...230 V "AC" "50/60 Hz" (AC-3)
  • 4 kW at 380...400 V "AC" "50/60 Hz" (AC-3)
  • 4 kW at 415...440 V "AC" "50/60 Hz" (AC-3)
  • 5.5 kW at 500 V "AC" "50/60 Hz" (AC-3)
  • 5.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3)
  • 2.2 kW at 400 V "AC" "50/60 Hz" (AC-4)
  • 2.2 kW at 220...230 V " AC" "50/60 Hz" (AC-3e)
  • 4 kW at 380...400 V "AC" "50/60 Hz" (AC-3e)
  • 4 kW at 415...440 V "AC" "50 /60 Hz" (AC-3e)
  • 5.5 kW at 500 V "AC" "50/60 Hz" (AC-3e)
  • 5.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3e)

Motor power in hp:

  • 1 hp at 230/240 V for 1 phase motors" AC" "50/60 Hz"
  • 2 hp at 200/208 V for 3 phase motors" AC""50/60 Hz"
  • 2 hp at 230/240 V for 3 phase motors" AC" "50/60 Hz"
  • 5 hp at 460/480 V for 3 phase motors" AC" "50/60 Hz"
  • 7.5 hp at 575/600 V for 3 phase motors" AC" "50/60 Hz"
  • 0.33 hp at 115 V for 1 phase motors" AC""50/60 Hz"

Conventional thermal current in open air:

  • 25 A at <60 °C for Power circuit
  • 10 A at <60 °C per signaling circuit

Rated Closing Power:

  • 250 A at 440 V for Power circuit in accordance with IEC 60947
  • 140 A "AC" for signaling circuit complying with IEC 60947-5-1
  • 250 A DC for signaling circuit complying with IEC 60947-5-1

Rated short-time allowable current:

  • 105 A at <40 °C - 10 s for Power circuit
  • 210 A at <40 °C - 1 s for Power circuit
  • 30 A at <40 °C - 10 min for Power Circuit
  • 61 A at <40 °C - 1 min for Power circuit
  • 100 A - 1 s per signaling circuit
  • 120 A - 500 ms per signaling circuit
  • 140 A - 100 ms per signaling circuit

Associated fuse gauge:

  • 10 A gG for signaling circuit complying with IEC 60947-5-1
  • 25 A gG at <= 690 V coordination Type 1 for Power circuit
  • 20 A gG at <= 690 V coordination Type 2 for Power circuit

Power dissipation per pole:

  • 1.56 W AC-1
  • 0.2 W AC-3
  • 0.2 W AC-3e

Rated insulation voltage:

  • 690 V complying with IEC 60947-4-1 Power circuit.
  • 600 V CSA certified Power circuit
  • 600 V UL certified Power circuit
  • 690 V complying with IEC 60947-1 signaling circuit
  • 600 V CSA certified signaling circuit
  • 600 V UL certified signaling circuit

Dimensions and weight:

  • Height: 77 mm
  • Width: 45 mm
  • Depth: 86 mm
  • Weight: 320 grams

  • Brand
  • Reference
    SNR LC1D09F7
  • In stock
    21 Items
  • EAN13
    3389110348798

  • Type
    Contactors
  • Voltage
    110VAC
  • Poles
    3P
  • Degree of protection
    IP20