LC1D09BD is a compact 3-pole TeSys D contactor from Schneider Electric for motor applications. Rated 9 A AC-3 4 kW at 400 V, it includes a 24 V DC coil and 1NA+1NC auxiliary contacts. Can be used in safety applications due to the certified NC mirror contact. Compact, DIN-rail-mounted, it ensures high reliability and durability. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium (RoHS/REACH) compliant.
Advantages:
- Compact product, 45 mm wide, for DIN rail and panel mounting.
- Separation between power and control circuits, easy front access to coil and auxiliary contact connections.
- Equipped with a 24 V DC coil for easy integration into all control systems.
- Features 2 built-in 1NA+1NC auxiliary contacts.
- High electrical durability, guaranteed for 2 million cycles at 9 A AC-3 440 V
Motor power:
- 2.2 kW at 220...230 V "AC" "50/60 Hz" (AC-3)
- 4 kW at 380...400 V "AC" "50/60 Hz" (AC-3)
- 4 kW at 415...440 V "AC" "50/60 Hz" (AC-3)
- 5.5 kW at 500 V "AC" "50/60 Hz" (AC-3)
- 5.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3)
- 2.2 kW at 400 V "AC" "50/60 Hz" (AC-4)
- 2.2 kW at 220...230 V "AC" "50/60 Hz" (AC-3e)
- 4 kW at 380...400 V "AC" "50/60 Hz" (AC-3e)
- 4 kW at 415...440 V "AC" "50/60 Hz" (AC-3e)
- 5.5 kW at 500 V "AC" "50/60 Hz" (AC-3e)
- 5.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3e)
Motor power in hp:
- 1 hp at 230/240 V for 1 phase motors" AC" "50/60 Hz"
- 2 hp at 200/208 V for 3 phase motors" AC""50/60 Hz"
- 2 hp at 230/240 V for 3 phase motors" AC" "50/60 Hz"
- 5 hp at 460/480 V for 3 phase motors" AC" "50/60 Hz"
- 7.5 hp at 575/600 V for 3 phase motors" AC" "50/60 Hz"
- 0.33 hp at 115 V for 1 phase motors "AC" "50/60 Hz"
Rated insulation voltage:
- 690 V complying with IEC 60947-4-1 Power circuit
- 600 V CSA certified Power circuit
- 600 V UL certified Power circuit
- 690 V complying with IEC 60947-1 signaling circuit
- 600 V CSA certified signaling circuit
- 600 V UL certified signaling circuit
Characteristics:
- Conventional thermal current in open air: 25 A at <60 °C for Power circuit - 10 A at <60 °C for signaling circuit
- Rated closing power Irms: 250 A at 440 V per IEC 60947-compliant Power circuit - 140 A "AC" per IEC 60947-5-1-compliant signaling circuit - 250 A DC per IEC 60947-5-1-compliant signaling circuit
- Rated breaking capacity: 250 A at 440 V per IEC 60947-compliant power circuit
- Associated fuse rating: 10 A gG for signaling circuit complying with IEC 60947-5-1 - 25 A gG at <= 690 V Type 1 coordination for Power circuit - 20 A gG at <= 690 V Type 2 coordination for Power circuit
- Time constant: 28 ms
- Minimum switching current: 5 mA per signaling circuit
- Minimum switching voltage: 17 V per signaling circuit
- No-overlap time: 1.5 ms upon deactivation between NC and NO contact - 1.5 ms upon activation between NC and NO contact
- Inrush power in W: 5.4 W 20 °C)
- Holding power consumption W: 5.4 W at 20 °C
- Insulation resistance: > 10 MOhm per signaling circuit
- Dimensions: height 77 mm - width 45 mm - depth 95 mm
- Weight: 480 grams
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent