• Siemens 6A 1P+N 4.5kA 30mA Residual current operated Circuit Breaker C AC
  • Siemens 6A 1P+N 4.5kA 30mA Residual current operated Circuit Breaker C AC

Siemens 6A 4.5KA 1P+N Type A 30ma Residual current operated Circuit Breaker 5SV13137KK06

€48.11
Tax included

Siemens Residual current operated circuit breaker, combined protection against short circuits, overloads and current leakage. Ideal for domestic and industrial installations, with the following characteristics:

  • Rated current: 6 amps

  • Number of poles: 1P+N

  • Operating voltage: 230V AC

  • Interrupting capacity: 4.5 kA

  • Differential current: 30 mA

  • Tripping curve: C

  • Differential type: A

  • Number of modules: 1

  • Degree of protection: IP20

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Comprehensive protection for your electrical system

The Siemens RCBO, integrates three basic protections:

  • Magnetic protection against short circuits, preventing fire and damage to the system
  • Thermal protection against overloads, preventing interruptions due to excessive loads
  • Differential protection (30mA) against current leakage, ensuring the safety of people

This combination makes it an essential device for electrical safety in homes, offices and small businesses.

Siemens RCBO: curve C and type A protection

C curve: ideal protection for mixed loads

Thanks to the C-curve tripping curve, the device is suitable for circuits with mixed loads, such as outlets and lighting, reducing the risks of unwanted interruptions.

Operation of the type A residual current circuit breaker

The A-type residual current device provides excellent protection against alternating sine and pulsating unidirectional leakage currents. This means that it can detect even leakage currents with continuous components, ensuring a higher level of safety than AC-type differential switches.

Siemens Residual current operated circuit breaker: robustness, reliability and compliance

Robust and compact design

Designed for quick and easy DIN-rail installation, the device is 2 modules wide, taking up little space in the electrical panel. Constructed with halogen- and silicone-free materials, it provides enhanced environmental safety and durability.

Certified reliability and regulatory compliance

Made in accordance with CEI EN 61008-1 standards, it ensures safe and timely tripping of sine-sine alternating differential currents. It has a mechanical life of 10,000 switching cycles, ensuring reliable performance over time.

Features of the Siemens RCBO

Technical Data

Feature Value
Rated current 6A
Number of poles 1P+N
Voltage 230V AC
Differential current 30 mA
Breaking capacity 4.5 kA
Tripping curve C
Type of differential A
Number of modules 2


Installation and Protection

Feature Value
Degree of protection IP20
Maximum cable cross-section 0.75/16 mm²


Dimensions

Feature Value
Height 90 mm
Width 18 mm
Depth 77 mm
Recessed depth 70 mm

  • Brand
  • Reference
    SIE 5SV13137KK06
  • In stock
    19 Items
  • EAN13
    4001869557649

  • Modules
    1
  • Poles
    1P+N
  • Curve
    C
  • Breaking capacity
    4.5KA
  • RCD Type
    A
  • Differential current
    0.03A
  • Amps
    6A
  • Circuit Protections
    RCBO

Comments (0)

No customer reviews for the moment.

16 other products in the same category

Viewed products

Loading...