• Hager Residual Current Operated Circuit Breaker 1P+N 25A 4.5kA 30mA C A

Hager Residual Current Operated Circuit Breaker 1P+N 25A 4.5kA 30mA Curve C Type A 2M ADA825H

€57.13
Tax included

Hager Residual Current Operated Circuit Breaker, combines magnetic, thermal and differential protection in one compact device. Ideal for the safety of electrical systems, it offers high reliability against overloads, short circuits and current leakage, with the following features:

  • Rated current: 25 amps

  • Number of poles: 1P+N

  • Operating voltage: 240V

  • Breaking capacity: 4.5 kA

  • Differential current: 30 mA

  • Tripping curve: C

  • Differential type: A

  • Number of modules: 2

  • Degree of protection: IP20

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Comprehensive protection for your system

The Eaton circuit breaker combines three essential functions in one device:

  • Magnetic protection: intervenes quickly in the event of a short circuit, preventing damage to cables and reducing the risk of fire
  • Thermal protection: protects against electrical power overloads, ensuring safe operation even with multiple appliances connected at the same time
  • Differential (life-saving) protection: with 30mA sensitivity, it effectively protects people from current leakage, preventing dangerous electric shocks

Hager RCBO: C curve, safety and easy installation

The Eaton Circuit Breaker, offers a complete and safe solution for domestic and commercial electrical systems. With its combined magnetic, thermal and differential protection, it provides high safety standards, ease of installation and long-term reliability.

Curve C and Differential Protection Type A

Curve C provides optimal protection in circuits with mixed loads, such as household outlets and lighting systems. It is perfect for loads with medium inrush currents (5-10 times rated current), preventing unwanted trips during normal operation.

Type A differential circuit breaker tripping is assured for alternating sinusoidal differential currents and unidirectional pulsating differential currents applied suddenly or slowly increasing (IEC EN 61008-1).

Easy installation and reliability over time

Compact size (2 modules): ideal for electrical panels with limited space. Quick DIN rail mounting: easy installation and maintenance. IP20 degree of protection: ideal for indoor environments, offers safety against accidental contact.

Hager RCBO Technical Specifications

Feature Value
Rated current 25A
Rated operating voltage 240 Vac
Rated frequency 50 Hz
Interrupting capacity Icn 4.5kA
Tripping curve C
Differential trip characteristic A
Rated differential current 30 mA
Number of poles 1P+N
Number of Modules 2
Tightening torque 2.1 Nm
Operating temperature -25/+40 degrees
Degree of protection IP20
Connection type Screw terminal
Height 83 mm
Width 35 mm
Depth 68 mm

  • Brand
  • Reference
    HAG ADA825H
  • In stock
    14 Items
  • EAN13
    3250611026754

  • Modules
    2
  • Poles
    1P+N
  • Curve
    C
  • Breaking capacity
    4.5KA
  • RCD Type
    AC
  • Differential current
    0.03A
  • Amps
    25A
  • Circuit Protections
    RCBO