Single-core cable AUE4CR 1x10 + 6C for fixed installation, XLPE insulated and PVC sheath, with the following characteristics:

  • Formation: 1x10 mm² + 6C

  • Conductor diameter: 3.5 mm

  • Insulation thickness: 1.2 mm

  • Sheath thickness: 1.4 mm

  • Max outer diameter: 13.2 mm

  • Electrical resistance at 20 degrees: 3.08 /km

  • Nominal voltage: 0.6/1 kV

  • ENEL registration number: 330101

The sale price is per metre.

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Cable AUE4CR reliability for energy transport in LV

The single-core cable AUE4CR is designed for low voltage (0.6/1 kV) energy transport and complies with the standards required for ENEL supplies. Made with a class 2 rigid aluminium conductor and a concentric copper conductor, it ensures excellent performance in both indoor and outdoor installations.

High-performance structure and materials

  • Phase conductor: Rigid aluminium (10 mm²)

  • Concentric conductor (neutral/screen): Red copper wires (6 mm²) with counter spiral tape

  • Sheath: Rz quality PVC

  • Sheath colour: Grey

This combination of materials ensures mechanical strength, flexibility, and durability over time, even in challenging environmental conditions.

Versatile installation for fixed laying

The AUE4CR cable is suitable for fixed laying in trays, pipes, or channels, both indoors and outdoors. It can also be buried, according to current regulations. The minimum bending radius is 14 times the outer diameter of the cable, ensuring flexibility during installation.

Technical Characteristics Single-core aluminium cable AUE4CR

Nominal voltage Uo/U = 0.6/1 kV
Maximum operating temperature (phase conductor) 90°C
Maximum concentric conductor temperature 85°C
Minimum operating temperature –15°C
Maximum short circuit temperature Phase conductor: 250°C – Concentric conductor: 160°C
Minimum bending radius 14 × Ø outer
ENEL registration number 330101
Formation 1 × 10 mm² + 6C
Conductor Ø 3.5 mm
Insulation thickness 1.2 mm
Sheath thickness 1.4 mm
Max outer Ø 13.2 mm
Indicative weight 170 kg/km
Electrical resistance at 20°C 3.08 Ω/km
Current carrying capacity at 30°C In air: 64 A – In pipe in air: 57 A – Buried: 68 A
Thermal short circuit current (1 s) Phase conductor: 0.9 kA – Neutral conductor: 0.8 kA

  • Brand
  • Reference
    9X9 AUE4CR/1X10-6C
  • In stock
    1655 Items

  • Colour
    Grey
  • Diameter
    13,2mm
  • Type
    Aluminum cables
  • Cross-Section
    10mmq
  • With yellow/green
    No
  • Number of cables
    1

Comments (0)

No customer reviews for the moment.

16 other products in the same category

Viewed products

Loading...