Ferrari professional sealant for A/C and refrigeration systems, in syringe with the following features:
Format: 42 ml syringe
Dosage: Multiple (can be used on multiple systems)
Gas compatibility: Wide (including R32, R410a, R134a)
Usage: A/C and refrigeration systems
Application: At low pressure valve
Condition of use: Vacuum test required
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
Turafall is the ideal product for the permanent repair of small refrigerant gas leaks in air conditioning and refrigeration systems. The formulation is polymer-free and provides maximum chemical compatibility with a wide range of refrigerants, ensuring safe and long-lasting intervention without side effects on the system.
The product is fully mixable with the following refrigerants:
R11, R12, R13, R14, R22, R23, R32, R123, R124, R134a, R141b, R404a, R407c, R410a, R422b, R424a, R502, R503, R507, R600
This compatibility makes it suitable for a wide range of applications, from single-split domestic systems to multi-split systems and commercial refrigeration.
Comes in a handy 42-mL syringe, which can be reused on multiple systems due to precise dosing.
Recommended doses:
12 ml: systems up to 0.3 kg of gas
24 ml: implants up to 0.45 kg
30 ml: single-split up to 1 kg
42 ml: multi-split up to 1.5 kg
60 ml: systems up to 3 kg
Over 3 kg: completely replace system oil with TURAFALL
A preventive test is mandatory to ensure the effectiveness of the product:
Connect a vacuum pump and bring the system to -1 bar
Wait at least 4 minutes to check the tightness of the system
If the leakage is too great (pressure not maintained), TURAFALL will not be effective
Once the test is passed:
Vacuum the system
Connect the syringe via adapter to the low-pressure valve
Inject the required amount
Charge the refrigerant gas
Turn the system on at full power for at least 30 minutes
| Format | 42 ml syringe |
| Dosage | Multiple, can be used on multiple systems |
| Gas Compatibility. | All major refrigerants, including R32, R410a, R134a |
| Usage | Professional - A/C and refrigeration systems |
| Type of sealant | Permanent, polymer-free |
| Safety | Does not damage compressors or gas recovery stations |
| Application | To low-pressure valve |
| Conditions of use | Prior vacuum test required |
| Operating temperature | According to plant specifications |