The Nice Smoke-Control is a universal optical detector designed to ensure maximum home safety. With dual detection technology (smoke and temperature) and compatibility with the Z-Wave protocol, it offers advanced protection against fire and danger:
Dual detection: photoelectric smoke sensor and built-in temperature sensor
Z-Wave compatible: can be integrated with smart home systems
Multiple alarms: beeping, flashing LED and sending notifications to the network
Real-time notifications: receive immediate alerts on your smartphone wherever you are
Battery powered: easily installed on ceilings or walls
Event analysis: records alarm data to prevent future risks
Compatible with Nice and Fibaro gateways (Home Center 3 - Home Center 3 Lite.)
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
The Nice Smoke-Control is equipped with a photoelectric sensor to quickly detect the presence of smoke and a temperature sensor that activates the alarm even in the absence of smoke. This provides comprehensive fire protection, including potentially critical situations such as localized overheating.
Upon detection of smoke or high temperatures, the device:
With smart home system integration, you can receive alerts on your smartphone wherever you are, ensuring a timely response.
Smoke-Control is battery-powered, making installation quick and easy on ceilings or walls (a minimum of 40 cm from the corner). Configuration with Z-Wave devices ensures seamless integration with pre-existing smart systems.
A distinguishing feature of Nice Smoke-Control is the ability to analyze risk event data. This feature helps identify and prevent similar situations in the future, improving home security in the long run.
Compatible with Z-Wave and Z-Wave Plus control systems;
3 levels of sensitivity, in accordance with EN 14604:2005;
Integrated housing opening detector;
Safety mechanism that prevents closing the case without the battery installed;
Alarm signaled by loud sound. LED indicator and message sent to Z-Wave network;
Additional feature of warning of temperature rise above a predetermined threshold;
Diagnostic efficiency test every 10 seconds to prevent possible malfunction;
Self-test functionality that can be implemented manually;
Recording of all temperature and smoke readings in the internal memory.
| Feature | Detail |
|---|---|
| Battery type | CR123A 3.0V DC (included) |
| Operating temperature | 0 ÷ 55 °C |
| Operating humidity | 0% ÷ 93% |
| Temperature measurement range | -20 ÷ 100 °C |
| Accuracy of temperature measurement | 0.5 °C |
| Smoke sensitivity |
|
| Sound intensity level | 85dB / 3m |
| Radio protocol | Z-Wave (500 series) |
| Radio frequency | 868.4, 869.85 MHz (EU) |
| Compliance |
|
| Radio range | Up to 40m (depending on building structure) |
| Dimensions | 65 Ø x 28 mm |