Advantages:
- On Line Technology (VFI) DSP
- 94% efficiency.
- Input/output 230/230Vac 50/60Hz
- Dimensions 19x57.3x36.9 cm
- Weight 46 kg
- Autonomy 10 min
- Contains 12 12Vdc 9Ah batteries
- Multifunction graphic LCD display
- Static bypass
- EPO contact for emergency shutdown, USB and RS232 communication ports for UPS control and power on/off programming using free TecnoManager software
- SNMP card
- Dry Contact or MODBUS (optional, in lieu of USB/RS232 card)
- Full protection from blackouts, voltage surges (overvoltage and undervoltage), lightning (with upstream arrester), frequency variations, surges, harmonics, voltage distortion
- Recommended for Local Area Networks (LAN), Data Centers, Industrial Processes, Electromedical
- Intelligent slot for SNMP, Dry Contact or MODBUS card
- Transformerless On-Line Double Conversion Technology (VFI-SS-111)
- Active PFC Circuit (0.99)
- Compatibility with generator set
- Static bypass
Technical data:
- Rated power 5.5 KVA
- Active power 4.95 KW
- Power Factor 0.9
- On-Line Double Conversion Transformerless Technology (VFI-SS-111)
- Forced Cooling by Fan
- Audible noise < 48 dBA at 1 m
- UPS Dimensions WxHxD 19x57.3x36.9 cm
- Dimensions with packaging WxHxD 33x83.5x50.5 cm
- Weight 46 kg
Input:
- Number of phases 1F+N
- Rated voltage 208Vac/220Vac/230Vac/240Vac
- Input voltage tolerance 176Vac-300Vac from 50% to 100% load, 110Vac-300Vac up to 50% load
- Rated frequency 50/60 Hz (selectable)
- Input frequency tolerance in On-Line mode ±7%
- Input power factor 0.99
Output:
- Number of phases 1F+N
- Rated voltage 208Vac/220Vac/230Vac/240Vac
- Voltage stability at %100 linear load (On-Line and battery mode) ±1%.
- Voltage harmonic distortion THD <3% (with linear load), <5% (with nonlinear load)
- Crest factor 3:1
- Frequency 50/60 Hz (selectable)
- Frequency stability ±0.1 Hz
- Waveform Inverter Sinusoidal
- Allowable overload (grid mode) 110% for 30 minutes, 130% for 5 minutes, >130% for 10 seconds
- Allowable overload (battery mode) 110% for 3 minutes, 130% for 30 seconds, >130% for 10 seconds
- Efficiency 94%, calculated in double conversion mode at 100% load according to 62040-3
- Trip Time 0 ms (On-Line)
Environmental operating conditions:
- Working temperature 0 to 55°C (for proper battery operation 20 to 25°C)
- Relative humidity < 95% non-condensing
- Maximum altitude 3000 m
- Degree of protection IP20
- CE certifications (Reference standards: safety IEC EN 62040-1; EMC IEC EN 62040-2; classification IEC EN 62040-3)