The surge arrester is a tool that can be mounted inside the electrical panel, thus upstream of the house system. Its use allows the electrical system on which it is installed to be protected.
The surge arrester will protect the entire system from surges, surges and spikes of electricity that may come from the power line operator, or from atmospheric phenomena such as lightning. These power anomalies can cause serious damage to devices connected to outlets.
A surge of electricity can cause the hardware of a pc to break, or short circuit the boards of smartphones, tablets, and home appliances. In the event that the flow of energy suddenly increases dramatically, human life may even be in danger due to electrocution. To prevent this from happening, it is therefore advisable to install a surge arrester.
Features:
- N-PE successive current extinguishing capacity: 0.1 kA
- Test class according to EN 61643-11: Type 2
- Rated leakage current (8/20 µs): 20 kA
- Rated leakage current (8/20 µs) L-N: 20 kA
- Rated leakage current (8/20 µs) N-PE: 40 kA
- Rated maximum discharge current (8/20 ?s): 40 kA
- Rated maximum discharge current (8/20 ?s) L-N: 40 kA
- Maximum rated discharge current (8/20 ?s) N-PE: 60 kA
- Mounting mode: 35 mm Omega profile
- Short-circuit resistant
- Cross-section of flexible conductor (fine-stranded) max: 35 mm²
- Cross-section of flexible conductor (fine-stranded) max: 2 AWG
- Section of flexible conductor (fine-stranded) min: 1.5 mm²
- Flexible conductor cross-section (fine-stranded) min: 16 AWG
- Rigid conductor cross-section (solid/braid wire) max: 35 mm²
- Rigid conductor cross-section (solid/braided cable) max: 2 AWG
- Rigid conductor cross-section (solid/braided cable) min: 16 AWG
- Operating temperature: -40/+80 degrees
- Response time: <25 ns
- Maximum continuous voltage (L-N): 280 V
- Maximum continuous voltage (N-PE): 255 V
- Maximum continuous AC voltage: 280
- Rated AC voltage (50/60 Hz): 230 V
- Line type for surge protectors: AC power line
- Rated discharge current (8/20 µs): 60 kA
- Overall protection level L-PE: 1.5 kV
- Maximum grid overcurrent protection: 160 A gL/gG
- Short-circuit with maximum grid overcurrent protection: 50 kA eff
- Rigid conductor cross-section (solid/braided cable) min: 1.5 mm²
Advantages:
- Installation for overvoltage protection according to VDE
- Discharge capacity up to 40 kA (8/20) per pole with high-performance varistors
- Modular, withdrawable complete with disconnection system and optical operation display
- Plug-in connection with vibration protection and voltage coding