The Chaffoteaux Mira Advance Link D2 35kW Gas Condensing Boiler is a highly efficient and versatile boiler designed to meet home heating needs. With its innovative SpinTech exchanger and Chaffolink connectivity, it offers advanced combustion control, ensuring maximum performance and energy savings:
Power: 35 kW
Seasonal efficiency: 94%
Compatible gases: Natural gas, LPG, propane air (without kit)
Exchanger: SpinTech stainless steel
Connectivity: Chaffolink integrated
Function: SRA (energy saving selection)
Installation: in partially protected places
Flue outlet: 80, 60, 50 mm, compatible with collective flues
Emissions: NOx Class 6 Ambient temperature: 0 to 40 °C
Energy class in heating: A+
Sanitary energy class: A
Withdrawal profile: XXL
Gateway: connectivity integrated into boiler
Natural gas, LPG and propane air operation without the need for a kit. Conversion is done through combustion control by selecting the gas type from the technical menu.
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
(modificale nel modulo Rassicurazioni cliente)
The Chaffoteaux Mira Advance Link D2 35kW features a single loop stainless steel primary exchanger with cross sections increased by 142% over the previous version. This allows for greater heat efficiency and long life. Seasonal efficiency of 94% and class A+ ensure low consumption and significant savings on utility bills.
With a 1:10 modulation ratio, this boiler provides optimal comfort by adapting to different thermal needs. Electronic combustion control through E-burning System D2 optimizes boiler operation, improving air quality and reducing harmful gas emissions. In addition, the SRA function improves energy efficiency, increasing comfort in the home.
The Mira Advance Link D2 is designed for easy and versatile installation. It can be installed in partially protected locations and supports a variety of flue gas discharge options, including kits for compatibility with positive pressure (C10) collective flues. In addition, it is compatible with 20% H2 hydrogen blends, further reducing environmental impact.
The boiler offers low pollutant emissions, thanks to its NOx class 6, which ensures low emissions of nitrogen oxides, contributing to a cleaner environment. In addition, the boiler is compatible with natural gas, LPG and propane air without the use of additional kits, making it a versatile choice for a variety of homes.
| Feature | Detail |
|---|---|
| CE Certification (pin) | 0085CR0394 |
| Connection Type | C13(X)-C23-C33(X)-C43(X)-C53(X)-C63(X), C83(X)-C93(X) B23-B23P-B33 |
| Feature | Detail |
|---|---|
| Max/min heating rated heat flow rate (Hi) | Qn kW 31/3.5 |
| Max/min rated heat flow rate in heating (Hs) | Qn kW 34.4/3.9 |
| Max/min nominal heat flow rate in DHW (Hi) | Qn kW 34.5/3.5 |
| Max/min DHW nominal heat flow rate (Hs) | Qn kW 38.3/3.9 |
| Max/min heating output (80°C-60°C) | Pn kW 30.3/3.3 |
| Max/min heating output (50°C-30°C) | P kW 33.5/3.6 |
| Max/min DHW output capacity | P 33,1/3,4 |
| Combustion efficiency (at flue gas) | % 97,9 |
| Efficiency at nominal heat input (60/80°C) Hi/Hs | % 98,1/88,3 |
| Efficiency at rated heat flow rate (30/50°C) Hi/Hs | % 107,8/97,1 |
| Efficiency at 30% of Qn with return at 30°C Hi/Hs | % 109,3/98,4 |
| Efficiency at idle (60/80°C) Hi/Hs | 94,2/84,8 |
| Losses at chimney burner operating | 2,1 |
| Characteristic | Detail |
|---|---|
| Residual evacuation head | Pa 100 |
| NOx class | 6 |
| Flue gas temperature (G20) (80°C-60°C) | °C 61 |
| CO2 content (G20) (80°C-60°C) | % 8,7 |
| CO content (0%O2) (80°C-60°C) | ppm 94 |
| O2 content (G20) (80°C-60°C) | % 5,5 |
| Maximum flue gas flow rate (G20) (80°C-60°C) | kg/h 60.2 |
| Air excess (80°C-60°C) | % 35 |
| Condensate pH | 3,2 |
| Max amount of condensates | l/h 3.88 |
| Feature | Detail |
|---|---|
| Expansion tank precharge pressure | bar 1 |
| Maximum heating pressure | bar 3 |
| Expansion tank capacity | l 8 |
| Min/max heating temperature (high temperature range) | °C 35 / 82 |
| Min/max heating temperature (low temperature range) | °C 20 / 45 |
| Feature | Detail |
|---|---|
| Sanitary temperature min/max | °C 36 / 60 |
| Specific flow rate in DHW (10 min. with ∆T=30°C) | l/min 16.5 |
| Instantaneous quantity of hot water ∆T=25°C | l/min 19.8 |
| Instantaneous quantity of hot water ∆T=35°C | l/min 14.1 |
| Minimum hot water withdrawal | l/min 2 |
| Max/min domestic water pressure | bar 7.0 / 0.2 |
| Feature | Detail |
|---|---|
| Power supply voltage/frequency | V/Hz 230 / 50 |
| Total electrical power consumption | W 93 |
| Energy efficiency index of circulator | EEI ≤ 0.23 |
| Minimum ambient temperature of operation | °C >0 |
| Electrical system degree of protection | IP X5D |
| Feature | Detail |
|---|---|
| Weight | 36 Kg |
| Feature | Detail |
|---|---|
| Plant delivery | Ø 3/4" gas |
| Sanitary outlet | Ø 1/2" gas |
| Gas inlet | Ø 3/4" gas |
| Sanitary inlet | Ø 1/2" gas |
| System return | Ø 3/4" gas |
check_circle
check_circle
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent