• Siemens 25A 4P 300MA K TYPE B Circuit Breaker 5SV36424

Siemens differential switch 25A 4P 300MA K type B 5SV36424

€563.27
Tax included

Pure differential switch Siemens, 4 modules, class K with short delay, DIN connection (universal for any switchboard on the market), poles 4P, 25 ampere, differential current Idn 300mA, voltage 400 Vac, differential type B.

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

The pure earth leakage circuit breaker is used to protect people and not the equipment. The moment a person goes to touch it, it creates a circuit with the earth. The current instead of remaining in the domestic circuit, uses the human body to go to earth.

The residual current circuit breaker, also called circuit breaker, is a device in your electrical system. It is able to open the circuit, i.e. to interrupt the supply of energy, when the current is accidentally lost.

A pure residual current circuit breaker offers protection in case of current leakage but not in case of overvoltage. For this type of problem, a circuit breaker is required instead.

For the earth leakage circuit breaker type B the intervention is assured as for the type F and for the following types of differential currents applied suddenly or slowly increasing:

  • Sinusoidal alternating with frequencies up to 1000 hz.
  • Alternating at rated frequency superimposed on a direct current levelled at 0.4 i∆n or 10 ma, whichever is higher. the earth leakage circuit breaker must trip at a value of the alternating current not exceeding i∆n.
  • The residual current device must trip at an alternating current value not exceeding 1.4 i∆n for residual current devices with i∆n > 10ma or not exceeding 2 i∆n for residual current devices with i∆n <= 10ma. (the value of the tripping differential current equal to 1.4 i∆n or 2 i∆n corresponds to the rms value of the half-wave of the unidirectional pulsating current).
  • Unidirectional pushbuttons that can be generated by rectifier circuits fed by two phases. the differential switch must trip within the limits of 0.5 i∆n and 2 i∆n.
  • Unidirectional pulses that can be generated by rectifier circuits fed by three phases. the residual current circuit breaker must intervene within the limits of 0.5 i∆n and 2 i∆n.
  • Continuous level switches produced by polyphase circuits. the residual current circuit breaker must trip within the limits of 0.5 i∆n and 2 i∆n.

Characteristics:

  • Siemens series
  • Voltage 400 Vac
  • Current In 25A
  • Idn differential current 300mA
  • Differential type B
  • 4 modules
  • 4P
  • Degree of protection IP20, for installation in distribution board, with conductors connected
  • Frequency of use 50 Hz
  • Height 90 mm
  • Width 72 mm
  • Depth 70 mm
  • Recessed depth 70 mm
  • Type of mounting DIN rail (REG)
  • Any mounting position
  • Tightening torque/with screw terminals min 2.5 Nm - max 3 Nm
  • Net weight 543 g

  • Brand
  • Reference
    SIE 5SV36424
  • In stock
    26 Items
  • EAN13
    4001869549064

  • Voltage
    400VAC
  • Modules
    4
  • Poles
    4P
  • RCD Type
    B
  • Differential current
    0.3A
  • Amps
    25A
  • Circuit Protections
    Residual current devices

Comments (0)

No customer reviews for the moment.