Other technical features:
- Mounting of contact or light elements: direct front mounting on button
- Contacts operation: slow opening
- Mechanical life: 1000000 cycles
- Description of ISO Terminals #1: (11-12) NC
- Weight: 0,02 kg
- Operating ambient temperature: -25/+70 °C
- Storage temperature: -40/+70 °C
- Vibration resistance: 15 gn (F= 10...500 Hz) compliant with IEC 60068-2-6
- Shock resistance: 100 gn according to IEC 60068-2-27
- Class of protection against electric shock: Class II in accordance with IEC 61140
Connections - terminals:
- Screw-fixing terminals, 1 x 2.5 mm² with or without cable end
- Screw-fixing terminals, 2 x 1.5 mm² with or without cable end
Contact code description:
- A600 AC-15, Ue = 240 V, Ie = 3 A acc. to IEC 947-5-1 appendix A
- A600 AC-15, Ue = 600 V, Ie = 1.2 A according to IEC 947-5-1 appendix A
- Q600 DC-13, Ue = 250 V, Ie = 0.27 A per IEC 947-5-1 Appendix A
- Q600 DC-13, Ue = 600 V, Ie = 0.1 A compliant with IEC 947-5-1 Appendix A
Rated operational power in W
- 40 W DC-13 for 1000000 cycles, operating range <3600 cycles/h at 120 V, load factor = 0.5 complies with IEC 60947-5-1
- 48 W DC-13 for 1000000 cycles, operating range <3600 cycles/h at 48 V, load factor = 0.5 according to IEC 60947-5-1
- 65 W DC-13 for 1000000 cycles, operating range <3600 cycles/h at 24V, load factor = 0.5 per IEC 60947-5-1
Reference Standards:
- EN/IEC 60204-32
- EN/IEC 60947-5-1
- CSA C22.2 No 14
- UL 508