• Schneider Residual current operated Circuit Breaker 16A 1P+N 6kA 30mA AC C

Schneider Acti9 Residual current operated Circuit Breaker 1P+N 16A 30MA AC 6KA A9DE3616

€143.26
Tax included

Siemens Residual current operated circuit breaker, combined protection against short circuits, overloads and current leakage. Ideal for domestic and industrial installations, with the following characteristics:

  • Rated current: 16 amps

  • Number of poles: 1P+N

  • Operating voltage: 230V AC

  • Interrupting capacity: 6kA

  • Differential current: 30 mA

  • Tripping curve: C

  • Differential type: AC

  • Number of modules: 2

  • Degree of protection: IP20

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Comprehensive protection for your electrical system

The Schneider Residual current operated circuit breaker, integrates three basic protections:

  • Magnetic protection against short circuits, preventing fire and damage to the system
  • Thermal protection against overloads, preventing interruptions due to excessive loads
  • Differential protection (30mA) against current leakage, ensuring the safety of people

This combination makes it an essential device for electrical safety in homes, offices and small businesses.

Schneider RCBO: C curve and AC type protection

C curve: ideal protection for mixed loads

Thanks to the C-curve tripping curve, the device is suitable for circuits with mixed loads, such as outlets and lighting, reducing the risks of unwanted interruptions.

Operation of the AC-type RCBO

This device is of the AC type, so it is sensitive to sine-sine alternating differential currents, ensuring rapid tripping in both sudden losses and gradual increases, ensuring high safety standards.

Schneider RCBO: robustness, reliability and compliance

Robust and compact design

Designed for quick and easy DIN-rail installation, the device is 2 modules wide, taking up little space in the electrical panel. Constructed with halogen- and silicone-free materials, it provides enhanced environmental safety and durability.

Certified reliability and regulatory compliance

Made in accordance with CEI EN 61008-1 standards, it ensures safe and timely tripping of sine-sine alternating differential currents. It has a mechanical life of 10,000 switching cycles, ensuring reliable performance over time.

Features of the Schneider RCBO

Technical Data

Feature Value
Rated current 16A
Number of poles 1P+N
Voltage 230V AC
Differential current 30 mA
Breaking capacity 6 kA
Tripping curve C
Type of differential AC
Number of modules 2


Installation and Protection

Feature Value
Degree of protection IP20


Dimensions

Feature Value
Height 85mm
Width 36 mm
Depth 73 mm

  • Brand
  • Reference
    SNR A9DE3616
  • In stock
    57 Items
  • EAN13
    3606489444235

  • Voltage
    230VAC
  • Modules
    2
  • Poles
    1P+N
  • Curve
    C
  • Breaking capacity
    6KA
  • Amps
    16A
  • Circuit Protections
    RCBO