• Bticino 4P 32A 30mA Residual current operated Circuit Breaker A 4.5kA 4M
  • Bticino 4P 32A 30mA Residual current operated Circuit Breaker A 4.5kA 4M

Bticino 4P 32A 30mA Residual current operated circuit breaker type A 4.5kA 4 modules GA8843A32

€299.26
Tax included

BTicino Residual current operated circuit breaker is an essential safety device for residential and industrial electrical systems. It integrates three protections in one module: magnetic (short circuits), thermal (overloads) and differential (current leakage), with the following characteristics:

  • Rated current: 32 amps

  • Number of poles: 4P

  • Operating voltage: 230V AC

  • Breaking capacity: 4.5 kA

  • Differential current: 30 mA

  • Tripping curve: C

  • Differential type: A

  • Number of modules: 4

  • Degree of protection: IP20

  • Universal DIN mounting: Compatible with any standard switchboard

  Politiche per la sicurezza

(modificale nel modulo Rassicurazioni cliente)

  Politiche per le spedizioni

(modificale nel modulo Rassicurazioni cliente)

  Politiche per i resi

(modificale nel modulo Rassicurazioni cliente)

Complete Protection: Magnetic, Thermal and Differential

This BTicino RCBO combines three protections in one device:

  • Magnetic protection against short circuits, preventing damage to the system and fire
  • Thermal protection against electrical power overloads (e.g., multiple appliances turned on)
  • Differential protection, safeguarding people against current leakage

BTicino BTDIN45 4P RCBO: Complete Protection

Maximum Safety with the BTDIN45

BTicino's BTDIN45 Residual current operated circuit breaker is designed to provide maximum safety in electrical systems. It combines the functions of circuit breaker and thermal-magnetic protection, preventing damage from overload, short circuit and current leakage.

Short Circuit and Overload Protection.

Magnetic protection intervenes quickly in the event of a short circuit, preventing overheating and fire. Thermal protection, on the other hand, limits overloads caused by excessive current draw, protecting the system and connected devices.

BTicino Residual current operated circuit breaker: Safe and Easy to Install

Differential Protection for Maximum Safety

Being a type A Residual current operated circuit breaker, it ensures tripping in case of alternating sine and pulsating unidirectional leakage currents, detecting both sudden and gradual leakage. This ensures effective protection against the risk of electrocution.

Easy Installation and Compatibility

With a width of 4 modules and a 4-pole configuration, the device is compatible with standard electrical panels. It supports cables up to 35 sq. mm, making it versatile for different types of installations.

Technical Features

Feature Value
Rated current 32A
Number of poles 4P
Differential current 30 mA
Breaking capacity 4.5 kA
Rated voltage 230 Vac
Type of differential A
Tripping curve C
Mounting Universal DIN (4 modules)
Degree of protection IP20
Maximum cable cross-section 25/35 sq. mm
Height 83 mm
Width 71.2 mm
Depth 76 mm

  • Brand
  • Reference
    BTI GA8843A32
  • In stock
    4 Items
  • EAN13
    8005543458587

  • Modules
    4
  • Poles
    4P
  • Curve
    C
  • Breaking capacity
    4.5KA
  • RCD Type
    A
  • Differential current
    0.03A
  • Amps
    32A
  • Circuit Protections
    RCBO

Comments (0)